4.29.0
PM compatibility version 1.35.1
New features
- Added support for Sungrow LC200 Multi PCS BCU protocol.
- Added new PV protocol for LIVOLTEK SunSpec.
- Added new BMS protocol for HuaSu S06.
- Added new parameter 7960 "DEIF Generic Offset", which allows you to select between higher and lower Modbus address spaces for the ESS protocol "DEIF Generic".
- Added new "Wait" status for the ESS protocol DEIF Generic. This status guarantees that the ASC does not send any start or stop signal over Modbus and triggers the "ESS NOT READY" status text in the display.
- Added new ESS protocol for Enjoy PCS.
- Added new BMS protocol for EVE MBMU BMS.
- Added new PV protocol Eachenergy PV. The protocol also supports some Chisage PV inverters.
- Added new ESS protocol Sungrow LC100 Utility v1.12.
- Added new BMS protocol for HuaSu Single Cluster.
- Added new BCU protocol for BESS Nomad
- Added new parameter 8400 "Maintenance Charge", which allows charging based solely on maximum charge capacity from BMS instead of SOC. This feature can be used to fully charge battery systems where the SOC is unreliable.
- Added new parameter 8401 "Charge capacity threshold", which sets a threshold in kW of the maximum charge capacity from BMS where 8400 "Maintenance Charge" shall adhere to stop charging.
- Added new M-Logic event set to true if genset load share in PMS is currently in reverse power.
- Added parameter set minimum genset cosphi in inductive range.
- Added M-Logic lines to skip Q-Ramping for batteries.
- Added new PV protocol for Hypontech PV inverter.
- Ningbo BMS will now read register 284 to check if communication between BMS and Golden Shield controller has been lost.
- Added new PCS protocol for WEG BIW610 PCS.
- Added new BMS protocol for WEG BMS.
- Added new protocol for Sungrow LC200 Single PCS
- Added new PV protocol Solis Logger.
- Added new BCU protocol for Kubank LEMS BCU.
- Added new protocol for Sungrow LC200 DPS
- Added new PV protocol for SAJ C6.
- Added new protocol for Moura BESS BCU.
Changes
- Parameter 6301 "Instant P max." is now enabled by default to allow derating the nominal power for battery by maximum dispatch or maximum charge power from BMS communication.
- ESS protocol Sinosoar SP100H now stops sending internal BMS telegrams when the BMS protocol is configured.
- Improved latency on reception of PMS telegrams.
Corrections
- KStar GSE 50-630 PCS protocol can now handle the transition from V/f to P/Q mode.
- Corrected issue where an Open PMS plant would not automatically give an auto start signal when the operation mode was peak shaving mode and the load was above the peak shaving set point.
- Corrected issue where BMS protocol Ningbo BMS would not connect/disconnect BMS racks.
- Fixed issue where Sinosoar SP100H was not able to read 112 registers in 1 telegram. The reactive power feedback and set point direction have also been corrected.
- Fixed an issue where ESB/PVB close fail alarm did not reset even when closing ES/PV breaker was not needed.
- Fixed incorrect scaling of active and reactive power set points when writing to LIVOLTEK SunSpec PV.
- Fixed an issue where Open PMS Solar controllers did not share auto start signals and did not start when an external mains was available.
- Solax MIC-G2/Pro-G2 PV protocol will be ready for operation when all PV inverters have been unlocked with password.
- Seven sensor 3S-TP and Seven sensor 3S-SI: Some addresses and data were missing and changed from the two weather stations.
- SinExcel PWS2 30K ESS protocol now supports Droop mode but only if Droop mode is set through M-Logic.
- M-Logic command 'Inh. PVB/ESB button' can now be read by the TDU. This requires TDU version 1.4.3.0 or later.
- Corrected an issue where parameter 2664 "U ref. gain" had no effect on voltage offsets for ESS protocols SinExcel PWS1, SinExcel PWS2 30K and SinExcel 30P.
- Corrected an issue where Huawei Smartlogger PV protocol did not support monitoring of multiple Huawei Smartlogger inverters.
- Fixed issue for the Sinexcel 30p protocol where the start and stop commands were not sent correctly.
4.29.0 |
10.01.2025 |
PM compatibility version 1.35.1 New features
Changes
Corrections
|
4.28.0 |
22.05.2024 |
PM compatibility version 1.33.0 New features 1- Added support for the Acrel ADL power meter protocol. Changes 1- Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol. It will now always use the VSG modes as intermediate modes, in between the required grid modes, to prevent the PCS from stopping. Corrections: 1- Corrected issue where the Megarevo MPS ESS protocol would reinitialize the start sequence of the PCS in a loop. |
4.27.2 |
01.03.2024 |
PM compatibility version 1.33.0 Corrections:
|
4.27.0 |
19.12.2023 |
PM compatibility version 1.33.0 New features:• Added support for using CAT EMCP 4 controllers directly as power meter.
Changes:• Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.
Corrections.• Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue. |
4.26.1 |
26.10.2023 |
PM compatibility version 1.30.0
Corrections
|
4.26.0 |
10.07.2023 |
PM compatibility version 1.30.0 New features
Changes
Corrections
|
4.25.0 |
09.02.2023 |
PM compatibility version 1.29.0 New features:
Changes:
Corrections:
|
4.24.0 |
24.11.2022 |
PM compatibility version 1.28.0 New features:
Changes:
Corrections:
|
4.23.1 |
15.09.2022 |
PM compatibility version 1.25.0 Corrections:
|
4.23.0 |
31.08.2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.22.0 |
03.05.2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.21.0 |
18.02.2022 |
PM compatibility version 1.25.0 New features: Changes: |
4.20.0 |
09.12.2021 |
PM compatibility version 1.24.2 New features:1- Sungrow LC100 BCU protocol added. Changes:1- Renamed "Ginlong Solis" PV protocol to "Solis (Ginlong)". |
4.19.0 |
22.11.2021 |
PM compatibility version 1.24.2 New features:
Changes:
Corrections:
|
4.18.0 |
20.09.2021 |
PM compatibility version 1.24.1 New features:
Changes:
Corrections:
|
4.17.1 |
16.07.2021 |
PM compatibility version 1.24.1. Corrections:1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter. |
4.17.0 |
28.06.2021 |
PM compatibility version 1.24.1. New features:
Changes:
Corrections:
|
4.16.0 |
08.04.2021 |
PM compatibility version 1.23.0. New features:
Changes:
Corrections:
|
4.15.1 |
25.02.2021 |
PM compatibility version 1.22.0. Corrections:
|
4.15.0 |
30.11.2020 |
PM compatibility version 1.22.0. New features:
|
4-14-2 |
29.10.2020 |
PM compatibility version 1.20.0 Corrections:
|
4.12.0 |
19.03.2020 |
PM compatibility version 1.16.0. New features:
|
4.11.3 |
28.01.2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.2 |
24.01.2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.1 |
31.10.2019 |
PM compatibility version 1.16.0. Corrections:
|
4.11.0 |
11.12.2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.10.1 |
16.04.2018 |
Corrections:
|
4.10.0 |
20.03.2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.05.2 |
12.01.2018 |
Corrections:
|
4.05.1 |
02.01.2018 |
PM compatibility version 1.15.0
|
4.05.0 |
30.11.2017 |
PM compatibility version 1.15.0 New features:
Corrections:
Changes:
|
4.04.0 |
05.10.2017 |
PM compatibility version 1.15.0 New features:1- Support of HiQ inverter. |
4.03.1 |
09.05.2017 |
PM compatibility version 1.15.0 Corrections:
|
4.03.0 |
03.04.2017 |
Version 4.03.0 New features:
Changes:
Corrections:
|
4.02.0 |
21.12.2016 |
PM compatibility version 1.15.0 New features:
Changes:
Corrections:
|
Auf dieser Seite können Sie Software-Updates für Ihr(e) Produkt(e) herunterladen und sich verschiedene Utility-Tools und Add-ons beschaffen, die Ihnen beim Einrichten und Konfigurieren Ihres Produkts/Ihrer Produkte sowie bei der entsprechenden Fehlersuche behilflich sein können.
Beachten Sie bitte, dass nicht alle unsere Produkte vom Benutzer aktualisiert werden können. Es werden auch nicht alle unsere Produkte mit einem Utility-Tool geliefert. Somit kann die Liste auf dieser Seite nicht als Übersicht unseres kompletten Produktsortiments angesehen werden.
DEIF registriert Ihren Download zusammen mit der verwendeten E-Mail-Adresse, um Ihnen auf Anfrage Informationen zu künftigen Updates zuzusenden.
DEIF kann nicht für die Folgen fehlgeschlagener Produkt-Updates oder die Nutzung von Utility-Tools haftbar gemacht werden. Auch haftet DEIF A/S nicht für die Folgen einer Verhaltensänderung von Produkten aufgrund eines Software-Upgrades. Es obliegt stets dem Anwender, vor der Inbetriebnahme die korrekte Einrichtung und Konfiguration sicherzustellen. Sehen Sie sich vor der Aktualisierung des Produkts das Versionsprotokoll der Software an.
Lizenzvereinbarung für den Software-Download von www.deif.com
Heruntergeladene Software bleibt Eigentum von DEIF. Die Software wurde möglicherweise nicht für gewerbliche Zwecke ausgegeben, sie wurde vollständig oder partiell geändert oder wiederverwendet oder sie wurde an jedwede Drittanbieter verkauft.Auf dieser Seite können Sie Software-Updates für Ihr(e) Produkt(e) herunterladen und sich verschiedene Utility-Tools und Add-ons beschaffen, die Ihnen beim Einrichten und Konfigurieren Ihres Produkts/Ihrer Produkte sowie bei der entsprechenden Fehlersuche behilflich sein können.
Die aktuellste Version für volle Funktionalität
Wir empfehlen Ihnen, die von uns bereitgestellten Updates zu installieren, um so das volle Potenzial Ihres DEIF-Produkts nutzen zu können.
Die gesamte optimierte Software kann nach Belieben unter www.deif.com heruntergeladen werden. Navigieren Sie dazu zu „Software“ und dann zu „Software-Download“.
Bei Fragen oder Problemen beim Auffinden der entsprechenden Software für Ihr Produkt wenden Sie sich telefonisch unter der Rufnummer +45 96149614 an DEIF A/S oder an die jeweilige lokale DEIF-Niederlassung. Alternativ können Sie uns auch eine E-Mail an support@deif.com senden. Wir helfen Ihnen gerne weiter.